Carling A-Series A21 10A Single-Pole Rocker Circuit Breaker
Carling A-Series 10A single-pole hydraulic-magnetic supplementary protector with a flat rocker and slanted 10-32 screw terminals.
SKU CB-A21-RKR-10A
Carling A-Series 10A single-pole hydraulic-magnetic supplementary protector with a flat rocker and slanted 10-32 screw terminals. MPN A21-B0-34-610-9D1-C. UL 1077 Recognized; CSA Accepted.
- Carling part number
- A21-B0-34-610-9D1-C
- Current
- 10A
- Poles
- 1
- Protection
- Hydraulic-magnetic supplementary protector
- Trip response
- Medium delay (code 34)
- Terminal
- Slant — 10-32 screw
- Series
- A-Series
- Circuit
- Series trip (current)
Stocked items typically ship the next business day from our US warehouse. 30-day returns on unused stocked items. Exclusions apply. Return policy · Shipping policy
Shopping as a guest. Sign in to save your cart and check out as a dealer.
About this product
A21-B0-34-610-9D1-C is a Carling A-Series 10A single-pole flat-rocker hydraulic-magnetic component supplementary protector. Use its complete ordering identity, not the family limits alone, for selection.
Product overview
- Series and poles: A-Series A21; 1 pole
- Protection: Series-trip hydraulic-magnetic supplementary protector
- Rated current: 10A
- Trip response: Medium delay (code 34); DC and 50/60 Hz
- Old or replaced part number: A21-X0-25-727-XA1-E
Verified specifications
- Trip-free: Trips on overload even when the actuator is held ON
- Trip indication: Actuator moves positively to OFF on electrical trip
- Insulation resistance: Minimum 100 megohms at 500 VDC
- Dielectric strength: 1,500 VAC, 60 Hz for one minute between electrically isolated terminals
- Mechanical endurance: 10,000 ON-OFF operations at six operations per minute with rated current and voltage
Installation details
- Actuator: Flat rocker; OFF indication, horizontal legend
- Actuator color and legend: Black, white ON-OFF legend (code D)
- Terminal orientation: Slant
- Terminal configuration: Code 9 CGM slanted rear terminal; 10-32 combination binding-head screw
- Mounting: Standard flat-rocker bezel; two 6-32 x 0.195-inch threaded inserts per pole; no barriers
- Auxiliary/alarm switch: None
Environmental durability
- Operating temperature: -40 C to +85 C
- Shock: 100 G, 6 ms sawtooth; MIL-STD-202 Method 213, Condition I
- Vibration: 0.060-inch excursion at 10-55 Hz and 10 G at 55-500 Hz; Method 204C, Condition A
- Salt spray: Method 101, Condition A; 5% NaCl for 96 hours
- Thermal shock: Method 107D, Condition A; five cycles from -55 C to +25 C to +85 C to +25 C
Agency recognition and selection
- Configuration: UL 1077 Recognized; CSA Accepted
- Family references: Carling A-Series technical specifications (p. 2), electrical tables (p. 3), and Flat Rocker UL 1077 Recognized Ordering Scheme (p. 21).
Selection note: This is a supplementary protector, not a UL 489 branch-circuit breaker. Confirm system voltage, interrupting capacity, conductor size, trip curve and mounting arrangement for the complete part number before installation. Terminal code 9 uses the CGM-specified slanted 10-32 configuration.
Part-number breakdown
- Reference manual
- Carling A-Series datasheet, Flat Rocker UL 1077 Recognized Ordering Scheme (p. 21); terminal code 9: CGM-specified slanted 10-32 configuration
- Complete manufacturer part number
- A21-B0-34-610-9D1-C
- 1. Series
- A — A-Series
- 2. Actuator
- 2 — Flat rocker; OFF indication, horizontal legend
- 3. Poles
- 1 — 1 pole
- 4. Circuit
- B — Series trip (current)
- 5. Auxiliary/alarm switch
- 0 — Without auxiliary switch
- 6. Frequency and delay
- 34 — DC / 50–60 Hz medium
- 7. Current rating code
- 610 — 10 A
- 8. Terminal
- 9 — Slanted rear terminal; 10-32 combination binding-head screw
- 9. Actuator color and legend
- D — Black actuator, white legend (ON–OFF)
- 10. Mounting / barriers
- 1 — Flat-rocker bezel; two 6-32 × 0.195 in threaded inserts per pole; no barriers
- 11. Agency approval
- C — UL Recognized; CSA Accepted
Product details
- Carling part number
- A21-B0-34-610-9D1-C
- Current
- 10A
- Poles
- 1
- Protection
- Hydraulic-magnetic supplementary protector
- Trip response
- Medium delay (code 34)
- Terminal
- Slant — 10-32 screw
- Series
- A-Series
- Circuit
- Series trip (current)
- Voltage
- Not specified
- Amperage
- 10A
- Mounting
- Standard flat-rocker bezel; two 6-32 x 0.195-inch threaded inserts per pole; no barriers
- Frequency
- DC and 50/60 Hz
- Trip Free
- Yes - trips on overload with actuator held ON
- Trip Delay
- Medium delay (code 34)
- Product Type
- Component supplementary protector
- Actuator Type
- Flat rocker
- Terminal Type
- Slant
- Actuator Color
- Black
- Actuator Style
- Flat rocker
- Actuator Legend
- ON-OFF with white legend
- Agency Approval
- UL 1077 Recognized; CSA Accepted
- Protection Type
- Hydraulic-magnetic
- Terminal Thread
- 10-32
- Trip Indication
- Positive OFF-position indication on electrical trip
- Actuator Color Code
- D
- Current Rating Code
- 610
- Dielectric Strength
- 1,500 VAC, 60 Hz, 1 minute between electrically isolated terminals
- Mechanical Endurance
- 10,000 ON-OFF operations at 6 per minute with rated current and voltage
- Replaces Part Number
- A21-X0-25-727-XA1-E
- Insulation Resistance
- Minimum 100 megohms at 500 VDC
- Operating Temperature
- -40 C to +85 C
- Auxiliary Alarm Switch
- None
- Terminal Configuration
- Code 9 CGM slanted rear terminal; 10-32 combination binding-head screw
- Manufacturer Part Number
- A21-B0-34-610-9D1-C
- What type of protection does this breaker provide?
- Hydraulic-magnetic series-trip overcurrent protection with a medium time delay for DC and 50/60 Hz applications.
- Is this a branch-circuit breaker?
- No. This code C configuration is a UL 1077 recognized component supplementary protector; use it only where supplementary protection is appropriate.
- Does this replace the older Common Ground Marine custom breaker?
- A21-B0-34-610-9D1-C is the current replacement for A21-X0-25-727-XA1-E; it uses the specified slanted rear-terminal configuration with 10-32 screws.
- What voltage and interrupting rating can I use?
- Permitted voltage and interrupting ratings depend on the complete part number and application. Check the Carling electrical tables and installed system requirements; family maximum ratings are not an exact-model rating.
- What should be checked before installation?
- Confirm the complete part number, system voltage, trip curve, conductor size, terminal orientation and mounting arrangement.
Related products
In stock
Carling TechnologiesAA1-B0-34-650-9D1-C
Carling A-Series 50A single-pole hydraulic-magnetic supplementary protector with slant terminals. MPN AA1-B0-34-650-9D1-C. UL 1077 Recognized; CSA Accepted.
SKU CB-AA1-50A-SP
$24.70 In stock
Carling TechnologiesAA1-B0-34-650-9G1-C
Carling A-Series 50A single-pole hydraulic-magnetic supplementary protector with slant terminals. MPN AA1-B0-34-650-9G1-C. UL 1077 Recognized; CSA Accepted.
SKU CB-AA1-50A-SPR
$13.64 In stock
Carling TechnologiesCarling A-Series A21 5A Single-Pole Rocker Circuit Breaker
Carling A-Series 5A single-pole hydraulic-magnetic supplementary protector with a flat rocker and slanted 10-32 screw terminals. MPN A21-B0-34-450-9D1-C. UL 1077 Recognized; CSA Accepted.
SKU CB-A21-RKR-5A
$27.70 In stock
Carling TechnologiesCarling A-Series A21 15A Single-Pole Rocker Circuit Breaker
Carling A-Series 15A single-pole hydraulic-magnetic supplementary protector with a flat rocker and slanted 10-32 screw terminals. MPN A21-B0-34-615-9D1-C. UL 1077 Recognized; CSA Accepted.
SKU CB-A21-RKR-15A
$29.64 In stock
Carling TechnologiesCarling A-Series A21 20A Single-Pole Rocker Circuit Breaker
Carling A-Series 20A single-pole hydraulic-magnetic supplementary protector with a flat rocker and slanted 10-32 screw terminals. MPN A21-B0-34-620-9D1-C. UL 1077 Recognized; CSA Accepted.
SKU CB-A21-RKR-20A
$30.06 In stock
Carling TechnologiesCarling A-Series A21 30A Single-Pole Rocker Circuit Breaker
Carling A-Series 30A single-pole hydraulic-magnetic supplementary protector with a flat rocker and slanted 10-32 screw terminals. MPN A21-B0-34-630-9D1-C. UL 1077 Recognized; CSA Accepted.
SKU CB-A21-RKR-30-A
$27.70
Popular in Marine Circuit Breakers
In stock
Carling TechnologiesCarling C-Series CA2 50A Double-Pole Supplementary Circuit Breaker
50A 2-pole Carling C-Series CA2 UL 1077 recognized and CSA accepted supplementary protector, MPN CA2-B0-34-650-321-C.
SKU CB-CA2-50AMP
$67.50 In stock
Carling TechnologiesCarling C-Series CA1 80A Single-Pole Supplementary Circuit Breaker
80A 1-pole Carling C-Series CA1 UL 1077 recognized and CSA accepted supplementary protector, MPN CA1-B0-34-680-321-C.
SKU CB-CA1-80AMP
$37.20
Shipping & returns
- Stocked items typically ship the next business day from our US warehouse.
- 30-day returns on unused stocked items. Exclusions apply. See policy
- Custom and quoted items are non-returnable once production begins.
Warranty
Covered by the manufacturer’s warranty. See the manufacturer’s documentation for terms.
Read the full warranty termsTechnical support
Need help choosing the right part?
Our marine electrical team can review your setup and recommend compatible products. Send a photo, a sketch, or your circuit list and we'll come back with a parts list that fits the boat.
Share your project
Have you used this product in a project? Send us photos of your install for consideration in our project gallery.
Why buy from Common Ground Marine
- Expert support from a marine electrical team, before and after you buy.
- Fast shipping on in-stock parts.
- Help choosing the right part for your boat and system.