Carling A-Series AM2 25A Double-Pole Sealed Toggle Circuit Breaker
SKU CB-AM2-25AMP - 501
Carling A-Series AM2 25A double-pole hydraulic-magnetic supplementary protector with a sealed metal toggle.
- Carling part number
- AM2-B0-34-625-501-C
- Current
- 25A
- Poles
- 2
- Protection
- Hydraulic-magnetic supplementary protector
- Trip response
- Medium delay (code 34)
- Terminal
- 10-32 Screw (Bus Type)
- Delay
- Medium
- Series
- A-Series
Contact us to confirm availability and shipping time. 30-day returns on unused stocked items. Exclusions apply. Return policy · Shipping policy
Shopping as a guest. Sign in to save your cart and check out as a dealer.
About this product
Carling A-Series AM2 25A double-pole hydraulic-magnetic supplementary protector with a sealed metal toggle. MPN AM2-B0-34-625-501-C. UL 1077 Recognized; CSA Accepted.
AM2-B0-34-625-501-C is a Carling A-Series 25A double-pole hydraulic-magnetic component supplementary protector with a sealed metal toggle. Its complete ordering identity, rather than the family limits alone, should be used for selection.
Product overview
- Series and poles: A-Series AM2; 2 poles
- Protection: Series-trip hydraulic-magnetic supplementary protector
- Catalog rated current: 25A
- Trip response: Medium delay (code 34)
- Frequency: DC and 50/60 Hz
- Catalog voltage: 250V AC / 80V DC
Verified specifications
- Trip-free: Trips on overload even when the actuator is held ON
- Trip indication: Actuator moves positively to OFF on electrical trip
- Insulation resistance: Minimum 100 megohms at 500 VDC
- Dielectric strength: 1,500 VAC, 60 Hz, 1 minute between electrically isolated terminals
- Mechanical endurance: 10,000 ON-OFF operations at 6 per minute with rated current and voltage
Installation details
- Terminal configuration: Code 5: 10-32 screw (bus type)
- Actuator: One per unit, on the right pole when viewed from the front
- Legend plate: None
- Mounting: Standard hex nut; no barriers
- Auxiliary/alarm switch: None
Environmental durability
- Operating temperature: -40 C to +85 C
- Shock: 100 G, 6 ms sawtooth; MIL-STD-202 Method 213, Condition I
- Vibration: 0.060 in excursion, 10-55 Hz; 10 G, 55-500 Hz; Method 204C, Condition A
- Salt spray: Method 101, Condition A; 5% NaCl, 96 hours
- Thermal shock: Method 107D, Condition A; five cycles, -55 C to +85 C
- Moisture resistance: Method 106D; ten 24-hour cycles at +25 C to +65 C, 80-98% RH; 56 days at +85 C, 85% RH
Agency recognition and selection
- Configuration: UL 1077 Recognized; CSA Accepted
- Selection: This is a recognized supplementary protector, not an assertion of UL 489 branch-circuit listing. Verify the complete part number, system voltage, trip curve, conductor size, terminals and mounting against the manufacturer documentation.
Part-number breakdown
- Reference manual
- Carling A-Series datasheet, Sealed Toggle UL Recognized Ordering Scheme (p. 14)
- Complete manufacturer part number
- AM2-B0-34-625-501-C
- 1. Series
- A — A-Series
- 2. Actuator
- M — Sealed toggle, one per unit; right pole on a two-pole unit
- 3. Poles
- 2 — 2 poles
- 4. Circuit
- B — Series trip (current)
- 5. Auxiliary/alarm switch
- 0 — Without auxiliary switch
- 6. Frequency and delay
- 34 — DC / 50–60 Hz medium
- 7. Current rating code
- 625 — 25 A
- 8. Terminal
- 5 — 10-32 screw (bus type)
- 9. Legend plate
- 0 — No legend plate
- 10. Mounting / barriers
- 1 — Standard hex nut; no barriers
- 11. Agency approval
- C — UL Recognized; CSA Accepted
Product details
- Carling part number
- AM2-B0-34-625-501-C
- Current
- 25A
- Poles
- 2
- Protection
- Hydraulic-magnetic supplementary protector
- Trip response
- Medium delay (code 34)
- Terminal
- 10-32 Screw (Bus Type)
- Delay
- Medium
- Series
- A-Series
- Circuit
- Series trip (current)
- Voltage
- 250V AC / 80V DC
- Amperage
- 25A
- Mounting
- Standard hex nut; no barriers
- Frequency
- DC and 50/60 Hz
- Trip Free
- Yes - trips on overload with actuator held ON
- Trip Delay
- Medium delay (code 34)
- Legend Plate
- None
- Product Type
- Component supplementary protector
- Actuator Type
- Sealed metal toggle
- Housing Color
- Black
- Terminal Type
- 10-32 Screw (Bus Type)
- Thermal Shock
- Method 107D, Condition A; five cycles, -55 C to +85 C
- Actuator Style
- Toggle
- Ul Recognition
- QVNU2, File E75596
- Agency Approval
- UL 1077 Recognized; CSA Accepted
- Protection Type
- Hydraulic-magnetic
- Trip Indication
- Positive OFF-position indication on electrical trip
- Shock Resistance
- 100 G, 6 ms sawtooth; MIL-STD-202 Method 213, Condition I
- Actuator Location
- One per unit, on the right pole when viewed from the front
- Csa Certification
- Class 3215 30, File 047848 0 000; CSA C22.2 No. 235
- Family Max Current
- 50 A
- Family Max Voltage
- 277 VAC / 80 VDC - configuration dependent, not an exact-model rating
- Current Rating Code
- 625
- Dielectric Strength
- 1,500 VAC, 60 Hz, 1 minute between electrically isolated terminals
- Moisture Resistance
- Method 106D; ten 24-hour cycles at +25 C to +65 C, 80-98% RH; 56 days at +85 C, 85% RH
- Mechanical Endurance
- 10,000 ON-OFF operations at 6 per minute with rated current and voltage
- Vibration Resistance
- 0.060 in excursion, 10-55 Hz; 10 G, 55-500 Hz; Method 204C, Condition A
- Insulation Resistance
- Minimum 100 megohms at 500 VDC
- Operating Temperature
- -40 C to +85 C
- Salt Spray Resistance
- Method 101, Condition A; 5% NaCl, 96 hours
- Auxiliary Alarm Switch
- None
- Terminal Configuration
- Code 5: 10-32 screw (bus type)
- Manufacturer Part Number
- AM2-B0-34-625-501-C
- Approximate Weight Per Pole
- 65 g / 2.32 oz
Related products
In stock
Carling TechnologiesCarling A-Series AM2 20A Double-Pole Sealed Toggle Circuit Breaker
Carling A-Series AM2 20A double-pole hydraulic-magnetic supplementary protector with a sealed metal toggle.
SKU CB-AM2-20AMP
$207.90 In stock
Carling TechnologiesCarling A-Series AM2 20A Double-Pole Sealed Toggle Circuit Breaker
Carling A-Series AM2 20A double-pole hydraulic-magnetic supplementary protector with a sealed metal toggle.
SKU CB-AM2-20AMP-501
$207.90 Low stock · 6 left
Carling TechnologiesCarling A-Series AM2 25A Double-Pole Sealed Toggle Circuit Breaker
Carling A-Series AM2 25A double-pole hydraulic-magnetic supplementary protector with a sealed metal toggle.
SKU CB-AM2-25AMP
$207.90 Usually ships 6-8 weeks
Carling TechnologiesCarling A-Series AM2 25A Double-Pole Sealed Toggle Circuit Breaker
Carling A-Series AM2 25A double-pole hydraulic-magnetic supplementary protector with a sealed metal toggle.
SKU CB-AM2-25AMP-34-501-I
$188.80 In stock
Carling TechnologiesCarling A-Series AM2 30A Double-Pole Sealed Toggle Circuit Breaker
Carling A-Series AM2 30A double-pole hydraulic-magnetic supplementary protector with a sealed metal toggle.
SKU CB-AM2-30AMP
$207.90 Low stock · 10 left
Carling TechnologiesCarling A-Series AM2 30A Double-Pole Sealed Toggle Circuit Breaker
Carling A-Series AM2 30A double-pole hydraulic-magnetic supplementary protector with a sealed metal toggle.
SKU CB-AM2-30AMP-501
$207.90
Popular in Marine Circuit Breakers
In stock
Carling TechnologiesCarling C-Series CA2 50A Double-Pole Supplementary Circuit Breaker
50A 2-pole Carling C-Series CA2 UL 1077 recognized and CSA accepted supplementary protector, MPN CA2-B0-34-650-321-C.
SKU CB-CA2-50AMP
$67.50 In stock
Carling TechnologiesCarling C-Series CA1 80A Single-Pole Supplementary Circuit Breaker
80A 1-pole Carling C-Series CA1 UL 1077 recognized and CSA accepted supplementary protector, MPN CA1-B0-34-680-321-C.
SKU CB-CA1-80AMP
$37.20
Shipping & returns
- Contact us to confirm availability and shipping time.
- 30-day returns on unused stocked items. Exclusions apply. See policy
- Custom and quoted items are non-returnable once production begins.
Warranty
Covered by the manufacturer’s warranty. See the manufacturer’s documentation for terms.
Read the full warranty termsTechnical support
Need help choosing the right part?
Our marine electrical team can review your setup and recommend compatible products. Send a photo, a sketch, or your circuit list and we'll come back with a parts list that fits the boat.
Share your project
Have you used this product in a project? Send us photos of your install for consideration in our project gallery.
Why buy from Common Ground Marine
- Expert support from a marine electrical team, before and after you buy.
- Fast shipping on in-stock parts.
- Help choosing the right part for your boat and system.