Double pole
    Carling AA2-B0-34-645-5D1-C A-Series 45 A double-pole black-toggle circuit breaker
    Carling Technologies

    AA2-B0-34-645-5D1-C

    Carling A-Series 45A double-pole hydraulic-magnetic supplementary protector with straight terminals.

    SKU CB-AA2-45AMP

    Our Price$42.79
    In stock

    Carling A-Series 45A double-pole hydraulic-magnetic supplementary protector with straight terminals. MPN AA2-B0-34-645-5D1-C. UL 1077 Recognized; CSA Accepted.

    Carling part number
    AA2-B0-34-645-5D1-C
    Current
    45A
    Poles
    2
    Protection
    Hydraulic-magnetic supplementary protector
    Trip response
    Medium delay (code 34)
    Terminal
    Straight
    Color
    Black
    Series
    A-Series

    Stocked items typically ship the next business day from our US warehouse. 30-day returns on unused stocked items. Exclusions apply. Return policy · Shipping policy

    Shopping as a guest. Sign in to save your cart and check out as a dealer.

    About this product

    AA2-B0-34-645-5D1-C is a Carling A-Series 45A double-pole hydraulic-magnetic component supplementary protector. Its complete ordering identity, rather than the family limits alone, should be used for selection.

    Product overview

    • Series and poles: A-Series AA2; 2 poles
    • Protection: Series-trip hydraulic-magnetic supplementary protector
    • Rated current: 45A
    • Trip response: Medium delay (code 34)

    Verified specifications

    • Trip-free: Trips on overload even when the actuator is held ON
    • Trip indication: Actuator moves positively to OFF on electrical trip
    • Insulation resistance: Minimum 100 megohms at 500 VDC
    • Dielectric strength: 1,500 VAC, 60 Hz for one minute between electrically isolated terminals
    • Mechanical endurance: 10,000 ON-OFF operations at six operations per minute with rated current and voltage

    Installation details

    • Terminal orientation: Straight
    • Terminal configuration: Code 5 straight 10-32 bus-type screw terminal
    • Mounting: Use the mounting arrangement encoded by the complete part number

    Environmental durability

    • Operating temperature: -40 C to +85 C
    • Shock: 100 G, 6 ms sawtooth, MIL-STD-202 Method 213 Condition I
    • Vibration: 0.060-inch excursion at 10-55 Hz and 10 G at 55-500 Hz, Method 204C Condition A
    • Salt spray: Method 101 Condition A, 5% NaCl for 96 hours
    • Thermal shock: Method 107D Condition A, five cycles from -55 C to +85 C

    Agency recognition and selection

    • Configuration: UL 1077 Recognized; CSA Accepted

    Part-number breakdown

    Reference manual
    Carling A-Series datasheet, UL 1077 Handle Ordering Scheme (p. 6)
    Complete manufacturer part number
    AA2-B0-34-645-5D1-C
    1. Series
    A — A-Series
    2. Actuator
    A — Handle, one per pole
    3. Poles
    2 — 2 poles
    4. Circuit
    B — Series trip (current)
    5. Auxiliary/alarm switch
    0 — Without auxiliary switch
    6. Frequency and delay
    34 — DC / 50–60 Hz medium
    7. Current rating code
    645
    8. Terminal
    5 — Straight orientation
    9. Actuator color and legend
    D — Black actuator, white legend (ON–OFF)
    10. Mounting / barriers
    1 — Two 6-32 × 0.195 in threaded inserts per pole; no barriers
    11. Agency approval
    C — UL Recognized; CSA Accepted

    Product details

    Carling part number
    AA2-B0-34-645-5D1-C
    Current
    45A
    Poles
    2
    Protection
    Hydraulic-magnetic supplementary protector
    Trip response
    Medium delay (code 34)
    Terminal
    Straight
    Color
    Black
    Series
    A-Series
    Voltage
    Not specified
    Amperage
    45A
    Trip Free
    Yes - trips on overload with actuator held ON
    Illumination
    Non-illuminated
    Product Type
    Component supplementary protector
    Actuator Type
    Handle, one per pole
    Housing Color
    Black
    Terminal Type
    Straight
    Actuator Color
    Black
    Actuator Style
    Toggle
    Protection Type
    Hydraulic-magnetic
    Trip Indication
    Positive OFF-position indication on electrical trip
    Pole Configuration
    Double pole
    Current Rating Code
    645
    Dielectric Strength
    1,500 VAC, 60 Hz, 1 minute between electrically isolated terminals
    Mechanical Endurance
    10,000 ON-OFF operations at 6 per minute with rated current and voltage
    Insulation Resistance
    Minimum 100 megohms at 500 VDC
    Operating Temperature
    -40 C to +85 C
    Terminal Configuration
    Code 5 straight 10-32 bus-type screw terminal
    Manufacturer Part Number
    AA2-B0-34-645-5D1-C

    Shipping & returns

    • Stocked items typically ship the next business day from our US warehouse.
    • 30-day returns on unused stocked items. Exclusions apply. See policy
    • Custom and quoted items are non-returnable once production begins.

    Warranty

    Backed by the original manufacturer’s warranty plus our workmanship guarantee on assembled harnesses. Contact us with your invoice and we’ll coordinate any covered repair or replacement.

    Read the full warranty terms

    Installation guidance

    These notes are a starting point. They cover the common considerations for a marine install — they don't replace a project review against your specific boat, helm, and circuit list.

    • Disconnect the battery and verify zero voltage at the working point before cutting or splicing.
    • Match wire gauge to the breaker and the run length, not just to the load.
    • Use marine-rated, tinned terminals and seal every crimp against moisture and vibration.
    • Route conductors clear of heat sources and protect them where they pass through bulkheads.

    Technical support

    Need help choosing the right part?

    Our marine electrical team can review your setup and recommend compatible products. Send a photo, a sketch, or your circuit list and we'll come back with a parts list that fits the boat.

    Certifications & training

    • ABYC-aware build practices
    • OEM-grade marine wire & terminals

    Additional capabilities are based on hands-on experience building marine wiring systems rather than third-party certification.

    Share your project

    Have you used this product in a project? Send us photos of your install for consideration in our project gallery.

    Why buy from Common Ground Marine

    • 20+ years building marine wiring harnesses, panels, and shore-power systems.
    • Engineers — not a phone tree — review every custom build before parts are cut.
    • OEM-grade components: tinned copper, sealed connectors, marine-rated jackets.

    Found in