Carling C-Series CA2 15A 120/240V AC 2-Pole UL 489 Circuit Breaker
SKU CB-CA2-UL-AC120/240-15A
- Carling part number
- CA2-B0-24-615-321-CG
- Current
- 15A
- Poles
- 2
- Voltage
- 120/240V AC
- Protection class
- UL 489 listed and CSA certified circuit breaker
- Terminal
- 1/4-20 stud
- Color
- Black
- Series
- C-Series
Stocked items typically ship the next business day from our US warehouse. 30-day returns on unused stocked items. Exclusions apply. Return policy · Shipping policy
Shopping as a guest. Sign in to save your cart and check out as a dealer.
About this product
15A 2-pole Carling C-Series CA2 120/240V AC UL 489 listed and CSA certified circuit breaker, MPN CA2-B0-24-615-321-CG.
Ordering-code details
- Application rating: 120/240V AC
- Actuator: One handle per pole; black handle with white legend
- Terminal: 1/4-20 stud
- Agency approval: UL 489 Listed and CSA Certified
Part-number breakdown
- Reference manual
- Carling C-Series datasheet, UL 489 Handle Ordering Scheme (p. 8)
- Complete manufacturer part number
- CA2-B0-24-615-321-CG
- 1. Series
- C — C-Series
- 2. Actuator
- A — Handle, one per pole
- 3. Poles
- 2 — 2 poles
- 4. Circuit
- B — Series trip (current)
- 5. Auxiliary/alarm switch
- 0 — Without auxiliary switch
- 6. Frequency and delay
- 24 — 50–60 Hz medium
- 7. Current rating code
- 615 — 15 A
- 8. Terminal
- 3 — 1/4-20 stud
- 9. Actuator color and legend
- 2 — Black actuator; white legend
- 10. Mounting
- 1 — 6-32 × 0.195 in threaded inserts; barriers on multipole units
- 11. Maximum application rating
- C — 120/240 V AC
- 12. Agency approval
- G — UL 489 Listed; CSA Certified
Product details
- Carling part number
- CA2-B0-24-615-321-CG
- Current
- 15A
- Poles
- 2
- Voltage
- 120/240V AC
- Protection class
- UL 489 listed and CSA certified circuit breaker
- Terminal
- 1/4-20 stud
- Color
- Black
- Series
- C-Series
- Amperage
- 15A
- Mounting
- Two 6-32 x 0.195-inch threaded inserts per pole; barriers
- Trip Free
- Yes - trips on overload with actuator held ON
- Actuator Type
- Handle, one per pole
- Terminal Type
- 1/4-20 Stud
- Agency Approval
- UL 489 listed and CSA certified circuit breaker
- Terminal Torque
- 30-35 in-lb (3.4-4.0 N-m)
- Trip Indication
- Positive OFF-position indication on electrical trip
- Dielectric Strength
- 1,960 V, 50/60 Hz, 1 minute between electrically isolated terminals
- Mechanical Endurance
- 10,000 ON-OFF operations at 6 per minute with rated current and voltage
- Insulation Resistance
- Minimum 100 megohms at 500 VDC
- Operating Temperature
- -40 C to +85 C
- Mounting Hardware Torque
- 7-9 in-lb (0.8-1.0 N-m)
Related products
In stock
Carling TechnologiesCarling C-Series CA2 7.5A 120/240V AC 2-Pole UL 489 Circuit Breaker
7.5A 2-pole Carling C-Series CA2 120/240V AC UL 489 listed and CSA certified circuit breaker, MPN CA2-B0-24-475-321-CG.
SKU CB-CA2-UL-AC120/240-7.5A
$84.15 In stock
Carling TechnologiesCarling C-Series CA2 10A 120/240V AC 2-Pole UL 489 Circuit Breaker
10A 2-pole Carling C-Series CA2 120/240V AC UL 489 listed and CSA certified circuit breaker, MPN CA2-B0-24-610-321-CG.
SKU CB-CA2-UL-AC120/240-10A
$84.15 In stock
Carling TechnologiesCarling C-Series CA2 10A Double-Pole DC UL 489 Circuit Breaker
10A 2-pole Carling C-Series CA2 UL 489 listed and CSA certified circuit breaker, MPN CA2-B0-14-610-321-BG, 125V DC.
SKU CB-CA2-UL-DC-10A
$84.15 In stock
Carling TechnologiesCarling C-Series CA2 15A Double-Pole DC UL 489 Circuit Breaker
15A 2-pole Carling C-Series CA2 UL 489 listed and CSA certified circuit breaker, MPN CA2-B0-14-615-321-BG, 125V DC.
SKU CB-CA2-UL-DC-15A
$84.15 In stock
Carling TechnologiesCarling C-Series CA2 20A 120/240V AC 2-Pole UL 489 Circuit Breaker
20A 2-pole Carling C-Series CA2 120/240V AC UL 489 listed and CSA certified circuit breaker, MPN CA2-B0-24-620-321-CG.
SKU CB-CA2-UL-AC120/240-20A
$84.15 In stock
Carling TechnologiesCarling C-Series CA2 20A Double-Pole DC UL 489 Circuit Breaker
20A 2-pole Carling C-Series CA2 UL 489 listed and CSA certified circuit breaker, MPN CA2-B0-14-620-321-BG, 125V DC.
SKU CB-CA2-UL-DC-20A
$84.15
Popular in Marine Circuit Breakers
In stock
Carling TechnologiesCarling C-Series CA2 50A Double-Pole Supplementary Circuit Breaker
50A 2-pole Carling C-Series CA2 UL 1077 recognized and CSA accepted supplementary protector, MPN CA2-B0-34-650-321-C.
SKU CB-CA2-50AMP
$67.50 In stock
Carling TechnologiesCarling C-Series CA1 80A Single-Pole Supplementary Circuit Breaker
80A 1-pole Carling C-Series CA1 UL 1077 recognized and CSA accepted supplementary protector, MPN CA1-B0-34-680-321-C.
SKU CB-CA1-80AMP
$37.20
Shipping & returns
- Stocked items typically ship the next business day from our US warehouse.
- 30-day returns on unused stocked items. Exclusions apply. See policy
- Custom and quoted items are non-returnable once production begins.
Warranty
Covered by the manufacturer’s warranty. See the manufacturer’s documentation for terms.
Read the full warranty termsTechnical support
Need help choosing the right part?
Our marine electrical team can review your setup and recommend compatible products. Send a photo, a sketch, or your circuit list and we'll come back with a parts list that fits the boat.
Share your project
Have you used this product in a project? Send us photos of your install for consideration in our project gallery.
Why buy from Common Ground Marine
- Expert support from a marine electrical team, before and after you buy.
- Fast shipping on in-stock parts.
- Help choosing the right part for your boat and system.